SIEMENS
3VL3720-1SL36-0AA0 - circuit breaker VL250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU12, LIG 3 phases/3 lines In=200A, rated current IR=80...200A, overload protection, II=1.25 to 11xIN, short-circui..
Cat No. 3VL3720-1SL36-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL8716-2TA40-0AA0 - circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU10, LIN In=1600A, rated current IR=640...1600A, overload protection, II=1.25 to 9 xIN, short-circuit protection N protected wit..
Cat No. 3VL8716-2TA40-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL5763-2TA46-0AA0 - circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU10, LIN In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection N protected withou..
Cat No. 3VL5763-2TA46-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL3720-2TA46-0AA0 - circuit breaker VL250H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU10, LIN In=200A, rated current IR=80...200A, overload protection, II=1.25 to 11xIN, short-circuit protection N protec..
Cat No. 3VL3720-2TA46-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL8716-2SB30-0AA0 - circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=1600A, rated current IR=640...1600A, overload protection, II=1.25 to 9 xIN, short-circuit protection without auxiliar..
Cat No. 3VL8716-2SB30-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL5763-2SB36-0AA0 - circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection without auxiliary r..
Cat No. 3VL5763-2SB36-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL2710-2SB36-0AA0 - circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU10, LI In=100A, rated current IR=40...100A, overload protection, II=1.25 to 11xIN, short-circuit protection with scre..
Cat No. 3VL2710-2SB36-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL7710-1TA46-0AA0 - circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU10, LIN In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected..
Cat No. 3VL7710-1TA46-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL4731-1TA46-0AA0 - circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU10, LIN In=315A, rated current IR=128...315A, overload protection, II=1.25 to 11xIN, short-circuit protection N p..
Cat No. 3VL4731-1TA46-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL2710-1TA46-0AA0 - circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU10, LIN In=100A, rated current IR=40...100A, overload protection, II=1.25 to 11xIN, short-circuit protection N pr..
Cat No. 3VL2710-1TA46-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL2706-1TA46-0AA0 - circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU10, LIN In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection N prot..
Cat No. 3VL2706-1TA46-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL6780-1SB36-0AA0 - circuit breaker VL800N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=800A, rated current IR=320...800A, overload protection, II=1.25 to 8 xIN, short-circuit protection without auxilia..
Cat No. 3VL6780-1SB36-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL3725-1SB36-0AA0 - circuit breaker VL250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU10, LI In=250A, rated current IR=100...250A, overload protection, II=1.25 to 11xIN, short-circuit protection with..
Cat No. 3VL3725-1SB36-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL2706-1SB36-0AA0 - circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU10, LI In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection with sc..
Cat No. 3VL2706-1SB36-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL2716-2DK36-0AA0 - circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 3-pole, starter combination Trip Unit magnetic In=160A, rated current II=1250...2500A, short-circuit protection with screw terminals without auxiliary release withou..
Cat No. 3VL2716-2DK36-0AA0 | Make: SIEMENS | ||
Stock: In Stock | Product Type: MCCB | ||
Quantity (Total: 1 Units) | Expected Delivery |
---|---|
1 Units | 5-7 Business Days |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL4731-1DK36-0AA0 - circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, starter combination Trip Unit magnetic In=315A, rated current II=2000...4000A, short-circuit protection without auxiliary release without auxiliary/alarm..
Cat No. 3VL4731-1DK36-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL2710-1DK36-0AA0 - circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, starter combination Trip Unit magnetic In=100A, rated current II=750...1500A, short-circuit protection with screw terminals without auxiliary release wit..
Cat No. 3VL2710-1DK36-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL4731-2EM46-0AA0 - circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit, TM, LI In=315A, rated current IR=250...315A, overload prot. II=1575...3150A, short-circuit protection N protected (100%) without a..
Cat No. 3VL4731-2EM46-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL1703-2EA46-0AA0 - circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=32A, rated current Ir=32A, overload protection II=300A, short-circuit prot. N protected with screw terminals without au..
Cat No. 3VL1703-2EA46-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL4731-2DC36-0AA0 - circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=315A, rated current IR=250...315A, overload protection, II=1575...3150A, short-circuit protection without auxiliary relea..
Cat No. 3VL4731-2DC36-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL1712-2DD36-0AA0 - circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=125A, rated current Ir=125A, overload protection II=1000A, short-circuit prot. with screw terminals without auxiliary r..
Cat No. 3VL1712-2DD36-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL1710-2DD36-0AA0 - circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=100A, rated current Ir=100A, overload protection II=1000A, short-circuit prot. with screw terminals without auxiliary r..
Cat No. 3VL1710-2DD36-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL2710-1EM46-0AA0 - circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=100A, rated current IR=80...100A, overload protection, II=500...1000A, short-circuit protection N protected with scre..
Cat No. 3VL2710-1EM46-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL2706-1EM46-0AA0 - circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=63A, rated current Ir=50...63A, overload protection, II=300...600A, short-circuit protection N protected with screw t..
Cat No. 3VL2706-1EM46-0AA0 | Make: SIEMENS | ||||
Stock: In Stock | Product Type: MCCB | ||||
Quantity (Total: 3 Units) | Expected Delivery |
---|---|
2 Units | 5-7 Business Days |
1 Units | 10-14 Business Days |
Reach out to us for project inquiries, Add to cart and click on send inquiry
3VL1710-1DD36-0AA0 - circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=100A, rated current Ir=80...100A, overload prot. II=1000A, short-circuit prot. with screw terminals without auxilia..
Cat No. 3VL1710-1DD36-0AA0 | Make: SIEMENS |
Stock: BackOrdered | Product Type: MCCB |
Reach out to us for project inquiries, Add to cart and click on send inquiry